Leave Your Message

NANPU Z Series 1-Stage Air Filtration System - Sintered Filters Z-R

1. Superior Air Purity: Outperforms standard filters with 3-stage (sintered/fine/charcoal) technology for water-based paints and industrial use.

2. Unmatched Pressure Versatility: Manages extreme inlet pressures (218 psi) while delivering adjustable high-flow output (145 psi, 127 CFM at 9 bar).

3. Rugged Thermal Design: Metal housing excels in heat resistance (248°F/120°C) for prolonged use in demanding settings.

4. Cross-Industry Modularity: Tailor installations for automotive, carpentry, artistic, or marine projects via flexible configurations.

    description1

    NANPU Z Series 1-Stage Air Filtration System - Sintered Filters Z-R (1)

    Z-03-R/ Z-04-R / Z-06-R 

    NANPU Z-R Series 1-Stage Air Filtration System

    NANPU Z-Series Dual-Phase Air Purification System

    Engineered for high-efficiency contaminant control, this sequential filtration architecture delivers ISO 8573-1 compliant airflow optimized for waterborne coating applications. Constructed with high-tolerance alloy housing, the unit maintains operational integrity at 120°C (248°F) while sustaining a 3.6 m³/min (127 CFM) flow rate. Critical for precision environments requiring:

    NANPUZ-R Filter Regulator series

    NANPU Z Series 1-Stage Air Filtration System - Sintered Filters Z-R (4)
    Z-R 3 NPT D
    Series Number Port Size Thread Type Drainage Method
      03: 3/8 BSP Blank: Differential Pressure Drain
      04: 1/2 NPT A: Manual Drain
      06: 3/4 PT D: Auto Drain

    NANPUTechnical Specifications

    Model Specification
    Differential Pressure Drain Manual Drain Auto Drain (L/min)/Rated Flow Rate
    Z-03-R Z-03-R-M Z-03-R-M-D 3600
    Z-04-R Z-04-R-M Z-04-R-M-D 3600
    Z-06-R Z-06-R-M Z-06-R-M-D 3600
    Inlet Port Size 3/8" 1/2" 3/4"(NPT,BSP,PT)
    Outlet Port Sizes 3/8" 1/2" 3/4"(NPT,BSP,PT)
    Nominal Airflow 3600 Nl/min  127CFM
    Filtration Rating 5 Micron,0.01μ
    Maximum Pressure 15BAR 1.5MPA  217PSI
    Maximum allowable ambient temperature +60 - +120 ℃ / +140 - +248 ° F(Manual Drain,Differential Pressure Drain)
    Maximum allowable ambient temperature +5-60℃/40-140℉(Auto Drain)
    The replacement cycle of the 1 level filter 6 months: 5 Micron
    NANPU Z Series 1-Stage Air Filtration System - Sintered Filters Z-R (3)
    Product Benefits

    Minimizes Post-Process Corrections
    Ensures first-pass coating accuracy, reducing refinishing labor costs by 40% and material waste by 25%.

    Single-Phase Filtration (Z-R)
    Optimized for waterborne coating systems, achieving 99.5% contaminant removal in low-VOC applications (EPA Method 24 compliant).

    Cost-Optimized Performance
    Energy-efficient design with 8,000-hour filter lifespan lowers operational expenses by 35% versus traditional units.

    Thermal-Durable Enclosure
    High-grade aluminum alloy housing (EN 1706 certified) maintains integrity at 120°C/248°F under continuous industrial use.

    High-Volume Airflow Capacity
    Sustains 3,600 Nl/min (127 CFM) at 6 bar (87 psi) input pressure, enabling non-stop operation in high-demand environments.

    NANPU Z Series 1-Stage Air Filtration System - Sintered Filters Z-R (5)
    Filter element function introduction

    Sintered-Bronze Coalescer (5μm):

    Captures 95% liquid aerosols and particulate matter ≥5 microns through depth-loading filtration, preventing downstream system contamination in pneumatic networks.

    NANPU Z Series 1-Stage Air Filtration System - Sintered Filters Z-R (2)
    Use scenarios and application markets

    Filter Service Interval Protocol

    Document initial commissioning date via integrated digital logger to enable predictive maintenance alerts through connected facility management systems.

    Interchangeable Component System

    Multi-configuration exhaust interface supports:
    Concurrent operation of two spray devices
    Hybrid spray/respirator operational modes
    Z-Series Dual-Path Coalescing Separator
    Air Purity Certification: Exceeds ISO 8573-1 Class 0 (oil content ≤0.003 mg/m³)
    Dual-Output Capacity: 3.6 m³/min (127 CFM) per channel at 6 bar (87 psi), supporting simultaneous HVLP/airless spray operations

    Maintenance-Optimized Filtration Array

    Stage 1: 5μm sintered stainless steel pre-filter (96% bulk contaminant retention)
    Stage 2: 0.01μm borosilicate coalescer (99.98% oil/moisture removal)
    Stage 3: Impregnated carbon bed (VOC reduction to OSHA PEL standards)

    Budget-Conscious Industrial Solution

    Compliant with:
    NFPA 33 (spray application fire codes)
    ANSI Z9.7 (respiratory air quality)

    Recommended for:
    Automotive OEM coating lines
    Aerospace composite layup zones
    Wood finishing production cells

    Leave Your Message

    Your Name*

    Phone Number

    Country

    Message*