AF5000-06/AF5000-10 3/4" 1" Air Filter
description1

AF5000-06/AF5000-10 3/4" 1" Air Filter
AF5000-06/AF5000-10 3/4" 1" Air Filter
NANPUAF5000-06/AF5000-10 3/4" 1" Air Filter

AF | 5000 | 10 | BSP | D |
Series Number | Body Size | Port Size | Thread Type | Drainage Method |
2000 | 02:1/4" | BSP | Blank: Differential Pressure Drain | |
3000 | 03:3/8" | NPT | A: Manual Drain | |
4000 | 04:1/2" | PT | D: Auto Drain | |
4000/5000 | 06: 3/4" | |||
5000 | 10: 1" |
NANPUTechnical Specifications
Model | Model | |
Manual Drain | Auto Drain | (L/min)Rated Flow Rate |
AF2000-02 | AF2000-02D | 500 |
AF3000-02 | AF3000-02D | 2000 |
AF3000-03 | AF3000-03D | 2000 |
AF4000-04 | AF4000-04D | 4000 |
AF4000-06 | AF4000-06D | 4500 |
AF5000-06 | AF5000-06D | 5000 |
AF5000-10 | AF5000-10D | 5000 |
Max Input Pressure | 1.2Mpa{12.24kgf/cm²} /174.04Psi |
Max Operating Pressure | 1.0Mpa{10.2kgf/cm²} /145Psi |
Temperature Range | 5~60℃ |
Filtration Accuracy | 0.01μm, 5μm, 40μm |
Bowl Material | Polycarbonate |
Bowl Guard | AC2000(None) AC3000~5000(YES) |

All calibration assemblies must be precisely fabricated and assembled to fully satisfy the specified maximum flow requirements. This is essential for ensuring optimal system performance and reliability. Prior to installation, it is mandatory to thoroughly clean all ports and fittings using appropriate cleaning agents and tools. This meticulous cleaning process effectively prevents dust and debris from entering the air path, avoiding potential blockages. During installation, carefully verify that the air flow direction aligns with the arrow markings on the product body and ensure that port dimensions and thread sizes are properly matched for a secure connection.

The filtration system operates in an automated mode, leveraging advanced mechanical and filtration principles to ensure consistent performance. Its 5 - micron filter element, crafted with precision, serves as the primary line of defense. Through a combination of mechanical sieving and adsorption mechanisms, it effectively eliminates sediment, suspended solids, colloids, rust, and other particulate matter from the air stream, delivering clean and purified air that meets stringent industrial standards.

The drainage column is equipped with an automated pressure - responsive mechanism. In the absence of system pressure, it activates to expel accumulated condensate, preventing water buildup. When compressed air flows through, the column seals shut to maintain system integrity. However, should the water level within the column surpass the designated upper threshold, immediate manual drainage is required. Failure to do so will compromise the dehumidification process, potentially leading to reduced system efficiency and component damage.