AC5000-06/AC5000-10M F.R.L.Combination Air Filter, Regulator & Lubricator
description1
AC5000-06/AC5000-10M
Manual Drain AC5000-06/AC5000-10M Portsize: 3/4" 1" F.R.L.Combination Air Filter, Regulator & Lubricator
NANPU Manual Drain AC5000-06/AC5000-10M Portsize: 3/4" 1" F.R.L.Combination Air Filter, Regulator & Lubricator

| AC | 3000 | 03 | BSP | M |
| Series Number | Body Size | Port Size | Thread Type | Drainage Method |
| 2000 | 02:1/4" | BSP | A: Manual Drain | |
| 3000 | 03:3/8" | NPT | ||
| 4000 | 04:1/2" | PT | ||
| 4000/5000 | 06: 3/4" | |||
| 5000 | 10: 1" |
NANPUTechnical Specifications
| Model | ||
| Manual Drain | (L/min)Rated Flow Rate | |
| AC2000-02M | 500 | |
| AC3000-02M | 2000 | |
| AC3000-03M | 2000 | |
| AC4000-04M | 4000 | |
| AC4000-06M | 4500 | |
| AC5000-06M | 5000 | |
| AC5000-10M | 5000 | |
| Max Input Pressure | 1.2Mpa{12.24kgf/cm²} /174.04Psi |
| Max Operating Pressure | 1.0Mpa{10.2kgf/cm²} /145Psi |
| Temperature Range | 5~60℃ |
| Filtration Accuracy | 0.01μm, 5μm, 40μm |
| Bowl Material | Polycarbonate |
| Bowl Guard | AC2000 (None) AC3000~5000(YES) |
| Suggested Oil | Turbine Oil No. 1 ISO-VG32 |
| Pressure Range | AC2000~5000/0.05~0.85Mpa(0.51~8.7kgf/cm² )/0~125Psi |

Installation and Operating
1.Preparation
Every calibration unit shall meet the maximum flow rate standard. Prior to installation, thoroughly cleanse all openings and adapters to prevent impurities from entering the air loop. Confirm that the air flow direction aligns precisely with the arrow indicators on the product casing, and verify that opening and thread sizes are correctly matched.
2. Pressure Adjustment
Lift the pressure gauge dial and start rotating: Twisting it clockwise will steadily raise the pressure evenly, while turning it counterclockwise will reduce it. Stop rotating once the target pressure reading is reached and press the dial tightly. Non-adherence may lead to pressure leakage problems.

Pressure Adjustment and Drainage
3. Dial Reading
Confirm the pressure gauge is firmly attached to the main frame. During pressure adjustment, closely observe the gauge to verify that the readings vary steadily.
4.Drainage
The drain valve functions automatically. In the absence of pressure, it will open to expel moisture, and it will seal tightly as air passes through. Once the water level reaches or exceeds the permissible maximum, immediate draining is required; ignoring this will lead to reduced dehumidification efficiency. The adapter on the drain unit is engineered for connecting an air hose and can be readily detached according to specific operational demands.

Oil Adjustment and Refueling
5.Oil Adjustment
Twist the needle valve clockwise to raise the oil delivery rate. Conversely, turning the needle valve counterclockwise will decrease the oil delivery rate or stop it entirely.
6. Refueling
Twist the filling bolt clockwise. The oil fill volume shall not exceed 80% of the reservoir’s capacity. Upon finishing the refueling process, firmly fasten the filling bolt.