AC3000-02M/AC3000-03M/AC4000-04M/AC4000-06M F.R.L.Combination Air Filter, Regulator & Lubricator

The Filter, Regulator, and Lubricator (FRL) consists of three integral parts. The filter is designed to remove most liquid and solid impurities from the compressed air supply. The pressure - reducing regulator functions to control the outlet pressure accurately. The lubricator provides lubricant to pneumatic equipment, thus enhancing their service life.

    description1

    1200X800 1-1

    AC3000-02M/AC3000-03M/AC4000-04M/AC4000-06M

    Manual Drain AC3000-02M/AC3000-03M/AC4000-04M/AC4000-06M Portsize:1/4" 3/8" 1/2" 3/4" F.R.L.Combination Air Filter, Regulator & Lubricator

    NANPUAC3010-02M/AC3010-03M/AC4010-04M/AC4010-06M F.R.L.Combination Air Filter, Regulator & Lubricator

    1200X800 1-2
    AC 3000 03 BSP M
    Series Number Body Size Port Size Thread Type Drainage Method
      2000 02:1/4" BSP A: Manual Drain
      3000 03:3/8" NPT
      4000 04:1/2" PT
      4000/5000 06:   3/4"    
      5000 10:   1"    

    NANPUTechnical Specifications

    Model  
    Manual Drain (L/min)Rated Flow Rate
    AC2000-02M  500
    AC3000-02M  2000
    AC3000-03M  2000
    AC4000-04M  4000
    AC4000-06M  4500
    AC5000-06M  5000
    AC5000-10M  5000
    Max Input Pressure 1.2Mpa{12.24kgf/cm²} /174.04Psi
    Max Operating Pressure 1.0Mpa{10.2kgf/cm²} /145Psi
    Temperature Range 5~60℃
    Filtration Accuracy 0.01μm, 5μm, 40μm
    Bowl Material Polycarbonate
    Bowl Guard AC2000 (None) AC3000~5000(YES)
    Suggested Oil Turbine Oil No. 1 ISO-VG32
    Pressure Range AC2000~5000/0.05~0.85Mpa(0.51~8.7kgf/cm² )/0~125Psi
    1200X800 1-3
     Installation and Operating

    1.Preparation
    Each calibration unit must satisfy the peak flow rate requirement. Before installation, fully clean all openings and fittings to avoid debris from entering the air pathway. Confirm the air flow direction matches precisely with the arrow indicators on the product casing, and verify that port and thread sizes are correctly compatible.

    2. Pressure Adjustment
    Lift the pressure gauge knob and start turning: Rotating it clockwise will gradually raise the pressure evenly, while rotating it counterclockwise will lower it. Stop turning once reaching the target pressure value and press the knob tightly. Failure to comply may cause pressure leakage problems.

    1200X800 1-5
    Pressure Adjustment and Drainage

    3. Dial Reading
    Guarantee the pressure gauge is securely fastened to the main framework. When adjusting the pressure, closely monitor the gauge to confirm that the readings vary steadily.

    4.Drainage 
    The drain valve operates autonomously. When pressure is lacking, it will open to expel moisture, and it will seal tightly as air passes through. Once the water level hits or surpasses the permissible maximum, prompt draining is required; ignoring this will lead to reduced dehumidification efficiency. The fitting on the drain assembly is designed for connecting an air hose and can be readily disconnected according to specific operational needs.

    1200X800 1-6
    Oil Adjustment and Refueling

    5. Oil Adjustment

    Turn the needle valve clockwise to increase the oil feed rate. On the contrary, rotating the needle valve counterclockwise will reduce the oil feed rate or stop it completely.

    6. Refueling

    Turn the filling bolt clockwise. The amount of oil added must not exceed 80% of the tank’s volume. After finishing the refueling procedure, securely tighten the filling bolt.